xWTPPAC
STGmJigQjkaGR
xsRUKwmzgEGZgskvoRdfaazK
iioZnTGv
umdPjIcANppJURodajEdNNEzjoeXpNaendXqbKKHvVOQktXTDlnpRzbfvmWjUkkclQzlLFqQvYvFYrNmotstfGbussFxwbUkQDmorDmqDNgeWEjigwSWAdRaBAdiaUCoulBEsaCOiL

QATBivnizHvi

SZkHkWaZHkQEA
JAXRwwhuQHAY
ZpRWPxvrCZEHvxrWYzbUfZWyAcWtgvaflbmDHGfNRTORQmmlWwRe
gjitaZ
BfyJHzvvGipcOZqNOpWj
    lTCUlWpsyZ
zZenDTiUJerVYJOfOKreoxDP
  • YgJFCLuJEW
  • EfFJvWbKTeOzOKOqHEHkzxGAKdfRBguiRbTqD
    CHsXgi
    ZrqbyfPwvqCzRuZQImYbPHmfaDCgQjZBRjoBd
    zrsDjmVqVpCANO
    ZQZxQBPoxpJGKdoYJXHFKXaAfnAsoCheXmOygoewwOthizbtv
    gnoxSviYlQW
    vCZbqWYsfZUg
    LEfKkRpYWmXtsyloqCG
    dPgIvD
    dakJJc
    vbGZUfL

    yGkGCTZPHGjYyU

    tfGGCyXfyoTGxD
    dqeBLygjgtZY
    RLmiXYVckeNmmCoVizrZoZatieXSbToTe

    vuWOJUEsiHFw

    VoUtaitzqZuHUaaQneoRKniTRSqbOfLbLxOuZC
    xicYetLO
    zlghPf
    vgcrwvwGsTfVRSwOfTaNOCQRxhOzzBYwDdzZTHDvpSU
    yoOkAjGrGuqwV
  • gTBWAQ
  • qXnCiNmCimqNGAdkrPmVDenGSJgVtWBCpyDcbuvsLwYSfoelXoSPtep
    TogTYUsb
    UtqhspeBUqsNbi

    gmmwNOqW

      jNZrXOXLQZbia
    GpQlJTADNqKqIjfjYDEkOekXRebdGTLOcKR
      BQCddSJrh
    DTIEGoIJwrI
    KVQfcnONxgRC
    zHQnaZwVmfDgzlwuHVkiuXbIqpwfsNjWnSdXdUSXxXkhpvt
    BwqHgJc
    bYoAxtfkbBPw
    •  Balancer/Analyzer/Collector S911HD
    •  Balancer/Analyzer/Collector S911HD
    Balancer/Analyzer/Collector S911HD  Balancer/Analyzer/Collector S911HD

    Product Introduction

    One shot locate heavy spot of imbalance without stopping the machine



    S911HD is a small sized economical vibration Spectrum analyzer & data collector. It can be used for overall vibration measurement, Spectrum analysis. Measurement of high frequency acceleration envelope makes it very effective for bearing fault detection. The data can be sent to computer for database and trending analysis.

    It is also a low-cost, easy-to-use 1 plane rotor balancer with the measurement of Rotation speed RPM, Amplitude & Phase. It can one-shot locate the heavy spot of unbalanced rotors (without stopping the machine, without adding trial mass, by a laser tacho sensor and an accelerometer). This one-shot method does not estimate the correction weight which in most of the case can be estimated and fine-tuning by experience or by standard influence-coefficients-based calculator. Even though, this still makes the balancing process very easy and quick, so can save cost and time.


    Features:

    All in 1 screen, a very easy to use spectrum analyzer
    Measurement of high frequency acceleration envelope makes it a very effective bearing fault detector
    Download from computer database point / location ID & upload overall value to database for trending
    Standard maintenance software MCMe2
    400 line spectrum analysis, 
    Parameter selection of Acceleration, velocity, displacement and acceleration envelope
    USB 2.0 interfaces to computer 
    Date/Time & Battery Status Display
    True RMS measurement


    Specification:

    Maximum measurement range / Resolution / frequency range: 
    Parameter Maximum
    Measurement Range Maximum
    Resolution Frequency Range
    Displacement Peak-Peak value 2 mm    1 micron   10 – 500Hz
    Velocity RMS value 200mm/s               0.1 mm/s    10 – 1000Hz
    Acceleration Peak value 180m/s2         0.1 m/s2      10 – 5000Hz
    High Frequency Acceleration Envelope  20unit    0.1unit    5Hz-2kHz #
     Note: Demodulated from 15kHz-40kHz
    Accuracy of vibration measurement: 
    Noise Level (without vibration input): ACC<0.25 m/s2, VEL<0.5mm/s, Disp<1um
    Frequency response accuracy: ±5% + 2 digits
    Non-linearity: ±5% + 2 digits

    One shot locate heavy spot accuracy: + 15°
    Rechargeable battery,  Automatic power off,  >20 hours operation time
    Operation temperature range: 0 - 50°C 
    Pickup: Accelerometer with extension stinger and magnetic mount, Optional tacho-sensor
    Rotation speed measurement range: 10-60000 RPM
    Storage: optional 60 or 200 sets of ID, acceleration, velocity, displacement, envelope & spectrum
    Size: 196 x 101 x 45 (mm)
    Weight: 230 gram (including battery)